Starting Point Formulation

UCAR Latex 300

High Quality Flat Wall Paint
Formulation Suggestion I-2279

Ingredients
Pounds
Gallons
Pigment Grind

Water

188.0
22.57

CELLOSIZE™ HEC ER-4400

1.0
0.09

Potassium Tripolyphosphate (KTPP)

1.5
0.07

Tamol 1124

5.0
0.51

TRITON™ Nonionic Surfactant CF-10

3.0
0.34

Drewplus L-475

2.0
0.26

Kathon LX (1.5%)

1.5
0.18

Sodium Carbonate

3.5
0.20

Ti-Pure R-900

200.0
6.00

Huber 70C

170.1
7.77

Duramite

100.0
4.44

Nyad 400

20.0
0.83

Water

87.0
10.44
Letdown

UCAR™ Latex 300

300.0
33.71

Drewplus L-475

2.0
0.26

UCAR POLYPHOBE™ TR-116

10.3
1.15

Water

93.3
11.20

Total:
1200.0
100.01


Paint Properties

Pigment Volume Concentration, %

64.1

Volume Solids, %

33.9

Weight Solids, %

54.5

Weight per Gallon, lb

12.0

Stormer, KU

90 - 95

ICI, poise

0.9

pH, equilibrated

7.8 - 8.2

Heat-Aged Stability, 2 weeks @ 140°F, KU

+3

VOC, g/L

<5
Film Properties

Sheen, 85°

5.4

Contrast Ratio, 3 mil

0.983

ASTM Scrub Cycles with shim

200-250

Flow and Leveling, Leneta

4

Sag Resistance

20

NOTICE: No freedom from any patent owned by Seller or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer's use and for ensuring that Customer's workplace and disposal practices are in compliance with applicable laws and other governmental enactments. Seller assumes no obligation or liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.