PERIMATE DI-A
PERIMATE™ DI-A is the STYROFOAM™ solution for insulating structure below ground. PERIMATE DI-A boards have vertical channels cut into one face, to drain water away, and a filter fabric bonded to the face to prevent soil particles blocking the channels.
The letter 'A' denotes Dow's environmentally advanced quality of blue extruded polystyrene insulation foams, which are blown with carbon dioxide. 'A' products have no impact on the ozone layer.
Further information on designing with PERIMATE DI-A insulation can be found at Insulating with STYROFOAM: structure below ground.
Safety Data Sheets
|
|
|
|
PERIMATE DI-A |
| Properties |
Standard |
Unit |
CE Code |
|
| Thermal conductivity* |
|
|
|
|
| ≤80mm |
BS EN 12667 |
W/mK |
λD |
0.035 |
| 81-120mm |
BS EN 12667 |
W/mK |
λD |
0.036 |
| >120mm |
BS EN 12667 |
W/mK |
λD |
– |
| Compressive strength at 10% or break (90 days) |
BS EN 826 |
kN/m2 |
CS(10Y)i |
300 |
| Design load |
|
|
|
|
| 2% maximum deflection (50 years) |
BS EN 1606 |
kN/m2 |
CC(2/1.5/50)σC |
– |
| Water vapour resistivity |
BS EN 12086 |
MNs/gm |
– |
825 |
| Water vapour diffusion resistance factor |
BS EN 12086 |
m |
MUi |
165 |
| Water absorption |
|
|
|
|
| Total immersion |
BS EN 12087 |
% vol |
WL(T)i |
<0.5 |
| Diffusion |
BS EN 12088 |
% vol |
WL(V)i |
<3 |
| Freeze/thaw, after 300 cycles |
BS EN12091 |
% vol |
FTi |
<1 |
| Dimensional stability |
|
|
|
|
| 48hrs at 70C/90%RH |
BS EN 1604 |
% |
DS(TH) |
<2 |
| 168hrs at 40kPa/70C |
|
% |
DLT(2)5 |
– |
| Density (aim) |
BS EN 1602 |
kg/m3 |
– |
45 |
| Dimensions |
|
|
|
|
| Length |
BS EN 822 |
mm |
– |
1250 |
| Width |
BS EN 822 |
mm |
– |
600 |
| Thickness |
BS EN 823 |
mm |
Ti |
60, 100, 120 |
| Fire classification |
BS EN 13164 |
– |
Euroclass |
E |
| Appearance |
|
|
|
|
| Surface |
|
|
|
grooved face with geotextile |
| Edge profile |
|
|
|
shiplap |
| Application |
|
|
|
basement walls, external |
The properties given are typical (unless stated otherwise). Results of tests described are available from Dow
* declared 90/90 value - BS EN 13164