ROOFMATE RL-X
ROOFMATE™ RL-X is the STYROFOAM™ solution for insulating single-ply roof decks. ROOFMATE RL-X boards provide a lightweight, rigid substrate beneath light-coloured single-ply polymeric membranes on flat or low slope metal decked roofs. The large area and high dimensional stability of ROOFMATE RL-X boards minimises the installation time as well as the number of fixings required.
ROOFMATE RL-X can also be used to insulate warm pitched roofs at rafter line. ROOFMATE RL-X boards are for installation above the rafters with ROOFMATE RL cut to size to fit between the rafters. The insulation is supplied in large boards for rapid coverage.
Safety Data Sheets
|
|
|
|
ROOFMATE RL-X |
| Properties |
Standard |
Unit |
CE Code |
|
| Thermal conductivity* |
|
|
|
|
| ≤80mm |
BS EN 12667 |
W/mK |
λD |
0.029 |
| 81-120mm |
BS EN 12667 |
W/mK |
λD |
0.029 |
| Compressive strength at 10% or break (90 days) |
BS EN 826 |
kN/m2 |
CS(10Y)i |
300 |
| Design load |
|
|
|
|
| 2% maximum deflection (50 years) |
BS EN 1606 |
kN/m2 |
CC(2/1.5/50)σC |
110 |
| Water vapour resistivity |
BS EN 12086 |
MNs/gm |
- |
825 |
| Water vapour diffusion resistance factor |
BS EN 12086 |
m |
MUi |
165 |
| Water absorption |
|
|
|
|
| Total immersion |
BS EN 12087 |
% vol |
WL(T)i |
<0.5 |
| Diffusion |
BS EN 12088 |
% vol |
WL(V)i |
– |
| Freeze/thaw, after 300 cycles |
BS EN12091 |
% vol |
FTi |
– |
| Dimensional stability |
|
|
|
|
| 48hrs at 70C/90%RH |
BS EN 1604 |
% |
DS(TH) |
<2 |
| 168hrs at 40kPa/70C |
BS EN 1605 |
% |
DLT(2)5 |
– |
| Density (aim) |
BS EN 1602 |
kg/m3 |
– |
38 |
| Dimensions |
|
|
|
|
| Length |
BS EN 822 |
mm |
– |
2500 |
| Width |
BS EN 822 |
mm |
|
600 |
| Thickness |
BS EN 823 |
mm |
Ti |
50, 60, 80, 120 |
| Fire classification – reaction to fire |
BS EN 13164
BS EN 13501 |
– |
Euroclass |
E |
| Appearance |
|
|
|
|
| Surface |
|
|
|
skin |
| Edge profile |
|
|
|
tongue and groove |
| Application |
|
|
|
Pitched roof insulation at rafter line
Flat roofs |
| Certification |
BBA Agrément |
|
|
87/1836 |
The properties given are typical (unless stated otherwise). Results of tests described are available from Dow
* declared 90/90 value - BS EN 13164