OPTIM™ Synthetic Glycerine - Thermal and Cubical Expansion

The following information charts cubical expansion of various glycerine-water solutions when partially frozen and the thermal expansion of glycerine with increasing temperature measured by its change in volume or density.

Cubical Expansion of Glycerine-Water Solutions When Partially Frozen

Cubical Expansion (16KB PDF)

Cubical Expansion

 

Thermal Expansion of Pure Glycerine

Thermal Expansion of Pure Glycerine (12KB PDF)

Thermal Expansion of Pure Glycerine
(°C) Vol.
(°C) Vol.
(°C) Vol.
0 = 10000
100 = 10530
200 = 11245
10 = 10045
110 = 10590
210 = 11330
20 = 10090
120 = 10655
220 = 11415
30 = 10140
130 = 10720
230 = 11500
40 = 10190
140 = 10790
240 = 11585
50 = 10240
150 = 10860
250 = 11670
60 = 10295
160 = 10930
260 = 11755
70 = 10350
170 = 11005
270 = 11840
80 = 10410
180 = 11080
280 = 11925
90 = 10470
190 = 11160
290 = 12010

 

 

 

Coefficient of Thermal Expansion for Glycerine

Coefficient of Thermal Expansion (Gravimetric) (12KB PDF)

Coefficient of Thermal Expansion (Gravimetric)
of Solutions of Glycerine and Water
Glycerine (%)
Change in Specific Gravity per Degree
15-20°C
15-25°C
20-25°C
100
0.000615
0.000615
0.000610
97.5
0.000620
0.000615
0.000605
95
0.000615
0.000615
0.000615
90
0.000610
0.000615
0.000620
80
0.000620
0.000615
0.000610
70
0.000580
0.000570
0.000565
60
0.000540
0.000545
0.000550
50
0.000485
0.000495
0.000510
40
0.000430
0.000435
0.000445
30
0.000370
0.000385
0.000400
20
0.000300
0.000315
0.000325
10
0.000230
0.000255
0.000280
Water
0.000180
0.000205
0.000230