Module Specifications
|
|
|
 |
| OMEXELL™ EDI- Performance 210 Specifications |
| Product Water Resistivity |
≥ 5Ω-cm |
≥ 15Ω-cm |
| Total Exchangeable Anions (TEA) |
≤ 25 ppm (CaCO3) |
≤ 8 ppm (CaCO3) |
| Based on standard test solution, actual module performance is based on specific feed water conditions. |
| |
| OMEXELL™ EDI-210 Feed Water Requirements |
| Parameter |
Specifications |
| pH |
5.0-9.0 |
| Hardness |
≤ 0.5 ppm (CaCO3 ) |
| Dissolved Silica |
≤ 0.5 ppm |
| TOC |
≤ 0.5 ppm |
| Free Cl2 |
≤ 0.05 ppm |
| Fe, Mn |
≤ 0.01 ppm |
| Turbidity, NTU |
≤ 0.1 |
| Oxidizer, mg/L |
None |
| Based on RO permeate feed water. |
|
|
| Module Operating Conditions |
| Parameter |
Specifications |
| Dilute Product Flow Rate |
6.6-10 gpm (1.5-2.2 m3/h) |
| Recovery Rate |
up to 95% |
| Inlet Temperature |
50-100°F (10-38°C) |
| Inlet Pressure |
36-80 psi (2.5-7.0 bar) |
| Dilute Pressure Drop |
22-36 psi (1.5-2.5 bar) |
| Concentrate Inlet Flow |
2.2-4.5 gpm (0.5-1.0 m3/h)
|
| Concentrate Pressure |
7-10 psi (0.5 - 0.7 bar) less than Dilute Pressure |
| Electrolyte Flush |
0.22-0.30 gpm (50-70 lpm) |
| Concentrate Conductivity |
250-600 μs/cm |
| Electrical Current |
9A |
| Maximum Working Voltage |
160V DC |
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
®™* Trademark of The Dow Chemical Company ("Dow") or an affiliated company of Dow